ORNET

Fiber Access Terminal (FAT, OTP-16 Fibers)

Technical Specifications (2 Inlet/16 Outlet)

TypeDetails
External Dimension ( W×D×H )Packing Size : 220 × 300 × 80 ( mm )
Weight1,400g
Possible CableMax 2ea ( Cable Diameter 3mm ~ 13mm )
Outgoing Ports For Drop CablesMax 16ea
Splice TrayMechanical / Fusion ( Slot No : 12ea )

Material

Material Of Outer BoxesPC + ASA
Tensile StrengthMin. 620kgf / cm²
Tensile ElongationMin. 80%
Flexural StrengthMin. 450kgf / cm²
Notched Iod ImpactMin. 35kgf / cm at room temperature

Mechanical Characteristics

TestConditionPerformance
Inlet Cable RetentionApply an axial load of D × 1,000N / 45 at 100cm from the edge of the box for 30 minutes.Cable shall not slide off the box more than 1cm. Optical loss shall be less than 0.2dB
Drop Cable RetentionApply an axial load of 5kg at 50cm from the edge of the box for 10 seconds.Cable shall not slide off the box more than 1cm. Optical loss shall be less than 0.2dB
VibrationVibration at frequency of 10Hz ~ 55Hz ~ 10Hz / 10min for an hour.No parts inside the box shall be separated, broken or bent. No screws shall be loosen. Optical loss shall be less than 0.2dB.
FallingCondition the assembled box at -20℃ ± 2℃ for 2 hours. Let the box fallen down to concrete ground from the 75cm height. Do the same test at 4 0℃ ± 2℃.There shall be no damage or crack on the box.
Temperature CyclingHighest temperature 70℃ ± 2℃ Lowest temperature : -20℃ ± 2℃ Duration : 72 hours Number of cycles : 9 cyclesThere shall be no damage or crack on the box.
Artificial Water FallingSpray artificial waters on the Assembled l/min from the distance of 50cm for an hour.There shall be no evidence of the presence of water inside the closure.

Functional Characteristics

Splice SlotsBoth mechanical and heat shrinkable sleeves could be assembled.
Fiber ArrangementMinimum bending diameter of assembled fibers shall be 30mm.
Patch Panel8pcs ~16pcs of SC type adapters could be assembled. (Except for 1 Inlet)
LockingA stainless-steel screw
Water ProofComply with IP65

​​​​​​​Environmental Tests

Temperature CyclingOperate the chamber temperature between 0 2℃ and -40 2℃. Put a box inside the chamber for 9 cycles (72 hours) Cycle (8 hours) : 1 hour 23℃ to -30℃ 2 hours at -30℃ hours -30℃ to 60℃ 2 hours at 60℃ 1 hour 60℃ to 23℃There shall be no visible mechanical or physical damage.
Salt Fog SprayThe box shall be exposed to a salt fog spray in accordance with KS D 9502 for 96 4 hours.There shall be no rust or impurities at the external surface of the closure
VibrationMeasure and record the initial baseline value of the optical attenuation of the fibers monitored in the cable. Then the box will be subjected to a forced vibration at frequency of 10Hz ~ 55Hz ~ 10Hz / 10min for 1 hour. Measure the fiber attenuation after the vibration stopped.The box and mounting hardware shall not exhibit any mechanical damage. There shall be no change in fiber attenuation greater than 0.2 after the end of vibration when compared with the initial baseline values.