g2201 isotope ANALYZER
G2201 Isotope Analyzer
The Picarro G2201-i isotope analyzer combines capabilities of two Picarro δ13C carbon isotope instruments for CO2 and CH4 into a single instrument. Now it’s easy and fast to capture the insights that only stable isotope ratios offer. Researchers can follow carbon as it moves from source to sink with a single instrument. The dual-purpose analyzer brings simplicity and speed to research. Its small size and robustness make it easy to transport to the field, where immediate results allow researchers to change course on-the-fly and achieve optimal results from limited-time field campaigns.
- Only
field-deployable analyzer for simultaneous high-precision δ13C
measurements in CO2 and CH4
- Three
measurement modes: CO2 only, CH4 only, and
CO2 and CH4 combined
- Excellent
precision at a fraction of IRMS operating cost—less calibration, less
maintenance, no consumables
The analyzer operates in one of three modes: 1) CO2 only, 2) CH4 only, and 3) CO2 and CH4 combined. In the combined mode, the measurement of CO2 and CH4 are interleaved every few seconds to produce a sampling rate that is faster than the gas turn-over time in the cavity. When the analyzer is in CO2 only mode or CH4 only mode, the precision improves, because more time is devoted to one molecule. In all modes, the analyzer precisely measures CO2, H2O and CH4 concentrations, with fewer calibration events than other spectral absorption-based instruments. The G2201-i analyzer can be paired with a variety of peripherals to extend and expand functionality.
SPECIFICATION
CO2 | CH4 | CO2–CH4 | ||||
Dynamic Range | Isotope-only mode | Isotope-only mode | Simultaneous mode | |||
CO2 Guaranteed Spec Range | 380–2,000 ppm | 200–2,000 ppm | 380–2,000 ppm | |||
CO2 Operational Range | 100–4,000 ppm | 0–4,000 ppm | 100–4,000 ppm | |||
CH4 Guaranteed Spec Range | 1.8–500 ppm | High Precision mode: 1.8–12 ppm | High Precision mode: 1.8–12 ppm | |||
High Dynamic Range mode: 10–1,000 ppm | ||||||
High Dynamic Range mode: 10–500 ppm | ||||||
CH4 Operational Range | 0–1,000 ppm | High Precision mode: 1.2–15 ppm | ||||
High Dynamic Range mode: 1.8–1,500 ppm | ||||||
H2O Guaranteed Spec Range | 0–2.4% | |||||
H2O Operational Range | 0–5% | |||||
CO2 | CH4 | CO2–CH4 | ||||
General | Isotope-only mode | Isotope-only mode | Simultaneous mode | |||
Measurement Interval | »3 sec | »5 sec | ||||
Ambient Temperature Dependence | Guaranteed <±0.06‰/ºC, typical <±0.025‰/ºC | |||||
Rise/Fall Time (10–90%/90–10%) | Typical »30 sec | |||||
Applications Considerations | Interference can occur for concentrations of H2O and CO2 well outside of the defined dynamic range, as well as other organics, ammonia, ethane, ethylene, or sulfur containing compounds. Users should verify with prepared lab samples. Please contact us to discuss the experimental conditions. Pressure drops in the instrument’s gas path can draw external air when this system is used in recirculating applications. |
mEASUREMENTS
·
δ13C
·
Carbon Dioxide (CO2)
·
Methane (CH4)
·
Isotopic Carbon Dioxide (iCO2)
· Isotopic Methane (iCH4)
APPLICATION
·
Atmospheric
Science
·
Emission Quantification
·
Agriculture & Soil Science
·
Ecology
· Food & Beverage
· Petrochemical