G2508 Gas Concentration Analyzer
The Picarro G2508 gas concentration analyzer provides simultaneous, precise measurement of nitrous oxide (N2O), methane (CH4), carbon dioxide (CO2), ammonia (NH3) at parts-per-billion (ppb), and water (H2O) vapor at parts-per-million (ppm) sensitivity with negligible drift for agriculture soil science, ecology, and emissions quantification.
- Simultaneous
and continuous measurement of N2O, CH4, CO2,
NH3 and H2O
- Parts-per-billion
sensitivity for excellent rate-of-rise quantification
- Rapid
response time and continuous measurements provide data at high temporal
resolution
- Operates
in open or closed systems and integrates easily with chamber systems
- Water
correction automatically reports dry gas mole fractions
Precision at 1 minute and 5
minutes is <10 and <5 ppb for N2O, <7 and <5 ppb for CH4,
<300 and <200 ppb for CO2, and <3 and <1 ppb for NH3.
Water correction software automatically reports dry gas mole fractions to help
reduce research complexity and consumable costs
![](https://ornets.com/wp-content/uploads/2022/03/G2508-Gas-concentration.jpg)
SPECIFICATION
Carbon Dioxide | None – Automated correction good to 20,000 ppm CO2 |
Methane | None – Automated correction good to 200 ppm CH4 |
Ammonia | None – Automated correction good to 2 ppm NH3 |
Ethane | 0.2 ppb N2O/ppm C2H6 tested up to 120 ppm |
Ethylene | 0.5 ppb N2O/ppm C2H4 tested up to 16 ppm |
Acetylene | Not for use with acetylene experiments |
Background Gas | Designed for use in ambient air, not for use with highly varying or enriched N2, O2, H2, or He |
ChemDetect™ Software | Unique Picarro algorithms detect and flag data which may be inaccurate due to spectroscopic interference |
Ambient Temperature | 10 to 35°C |
Ambient Humidity | <85% RH, non-condensing |
Sample Pressure | 300 to 1,000 Torr (40 to 133 kPa) |
Sample Flow Rate | ~230 sccm |
Sample Humidity | <99% RH, non-condensing, Water correction tested to 25°C dew point |
Sample Temperature | -10 to 45°C |
Cavity Temperature Control | +/-0.005°C |
Cavity Pressure Control | +/-0.0002 atm |
Closed-loop/Recirculation Capability | Compatible with Picarro Closed System Pump A0702 |
Inlet Fittings | ¼” Swagelok® |
Dimensions | 17” w x 7” h x 17.5” d (43.2 x 17.8 x 44.6 cm) not including 0.5” feet |
Weight | 50 lbs (22.6 kg) |
100 –240 VAC; 47– 63 Hz (auto-sensing); < 375 W at start-up (total). Steady-state operation: 120 W (analyzer), 150 W (pump). | |
Power Requirements | |
Installation | Benchtop (standard) or 19” rack mount chassis (optional) |
Accessories | Included: Keyboard, mouse. Optional: LCD monitor. Excluded: Vacuum pump |
A0702, Picarro Closed System Pump | |
Options | S0528, O2 sensor for O2 measurements and correction in varying O2 environments S0517, Extended CH4 operating range up to 800 ppm |
mEASUREMENTS
·
Carbon Dioxide (CO2)
·
Methane (CH4)
· Water H2O
· Nitrous oxide (N2O),
APPLICATION
·
Emission Quantification
·
Agriculture & Soil Science
·
Ecology