Spectis Touch 1.0
GL Spectis Touch 1.0
The GL SPECTIS 1.0 Touch is an Android-based,
hand-held spectrometer for light assessment in the UV VIS range. On the display
you can monitor the SPD, color coordinates according to CIE standards, lux
value, CCT and CRI indices. The units include spectral calibration and we offer
additional accessories for luminous flux and luminance measurements. You can
use this as a stand-alone unit and check these values on the display.
SPECIFICATION
Spectral Range | 340 – 780 nm or 640 – 1050 nm |
Detector | Detector CMOS image sensor |
Number of pixels | 256 |
Physical resolution | ~ 1.7 nm |
A/D conversion | 16 bits |
Integration time | 10 ms – 10 s in automatic mode (100 s in manual mode) |
Signal-to-noise ratio | 1000:01:00 |
Stray light | 2*10 E-3 |
Operating System | Android |
Power supply | Input: AC 100-240V 50/60 Hz 0.15 A Output: 5 V-1 A |
Dimensions | 74 mm x 146 mm x 24 mm |
Weight | 349 g |
Display | LCD (240 x 320px) |
Application
-
Natural light
LEDs
Halogen light, etc.
FEATURE
-
Natural light
-
High sensitivity and precise calibration
-
Low noise and stable measurements
-
Ready to work when connected to PC (after about 10 min)
-
Small size and low energy consumption
-
Powered via USB connection
spectis 1.0 touch+flicker
The world’s most accurate handheld spectrometer just got better. The GL SPECTIS 1.0 Touch + Flicker simplifies light source flicker measurement. This reliable and versatile version integrates flicker quantification with the same intuitive touch screen interface of our successful GL SPECTIS 1.0 product line that includes accurate absolute spectral measurements. If you need to measure light flicker and other light qualities such as: lux, lumen, CCT, CRI, chromaticity coordinates, mWatt and much more, our highly portable and precise GL SPECTIS 1.0 Touch + Flicker is the ideal solution.
SPECIFICATION
Wavelength reproducibility | 0.5 nm |
Detector | Detector CMOS image sensor |
Number of pixels | 256 |
Physical resolution | ~ 1.7 nm |
A/D conversion | 16 bits |
Integration time | 10 ms – 10 s |
Signal-to-noise ratio | 1000:01:00 |
Stray light | 2*10 E-3 |
Operating System | Android |
External power supply | USB mini socket: 5V, 1A |
Dimensions | 74.5 mm x 145.5 mm x 36.6 (with standard diffusor) |
Weight | 349 g |
Display | 3.5“ color LCD (240 x 320px) |
feature
High sensitivity and precise calibration
Low noise and stable measurements
-
Ready to work when connected to PC (after about 10 min)
-
Small size and low energy consumption
-
Powered via USB connection
includes
· Certificate of calibration to reference standard
· Cosine-corrected standard diffuser head
(illuminance)
· Versatile interfaces: USB, SD card
· Remote trigger socket
· Universal mount for tripod or optical bench use
· Rugged case, charger, cable
· 1-year warranty with extension options
Spectis 5.0 Touch
With the new GL SPECTIS 5.0 Touch, we expanded our smart touch screen technology into laboratory grade equipment. The wide wavelength range allows for measurements in accordance with a number of standards, including Photobiological Safety (EN 62471) or measurement of SSL products (IESNA LM-79-08, CIE S 025/E:2015).
SPECIFICATION
Spectral Range | 340 – 850 nm (VIS) 200 – 800 nm (UV-VIS) 380 – 1050 nm (VIS-NIR) 200 – 1050 nm (UV-VIS-NIR) |
Detector | Detector CMOS image sensor |
Sensor | Back-thinned type CCD image |
Physical resolution | ~ 0.5 nm |
A/D conversion | 16 bits |
Number of pixels 2048 | 2048 |
Display | 3.5“color LCD 240 x 320 |
Micro SD card | 4GB |
Radiometric accuracy | **/***/**** 6 % within range 200 – 220 nm 5 % within range 220 – 500 nm 4 % within range 500 – 1050 nm |
Weight | 1556 g |
Power supply Input | AC 100-240V 50/60 Hz 0.15 A Output: 5 V-1 A |
Display | 3.5“ color LCD (240 x 320px) |
APPLICATION
· Special applications in the measurement of light
sources and optical components,
laboratory grade
FEATURE
-
Touch screen display
-
Automatic accessory detection
-
Dark current compensation
-
Trigger socket
-
Universal mount
- Small size and low energy consumption
-
Photometric and radiometric calibration
SPECTIS 8.0 SPECTRORADIOMETER
he USB controlled spectroradiometer includes
Peltier cooled CCD Back-Thinned sensor and silica transmission grating
delivering high resolution and increased sensitivity of the system. Cooling of
the sensor allows to set longer integration times to support low signal level
measurements. The perfect solution for scientific and laboratory applications
SPECIFICATION
Sensor | Back-thinned type CCD image sensor with cooling (5°C) |
Illuminance (lux)* | 3 lx – 150 000 lx |
Spectral range** | 250 – 1050 nm |
Number of pixels | 2048 |
FWHM | ~ 2.0 nm |
Wavelength reproducibility | ± 0.2 nm |
Integration time | 10 ms – 10 s |
A/D converter | 16 bit |
Signal-to-noise ratio | 2000:01:00 |
Stray light | 2*10 E-4 |
Radiometric accuracy**/*** | ± 2 % |
Uncertainty of color coordinates | ± 0.001 |
GENERAL PROPERTIES | |
Automatic accessory detection | ✓ |
External power supply | Input: AC 100…240 V (50/60 Hz) 1.5 A |
Output: DC 12V 10A | |
Operating temperature | 5 – 30 °C |
Dimensions [H x W x D] | 272 mm x 180 mm x 327 mm (± 3mm) |
Weight | 6.4 kg |
INTERFACE & MEMORY | |
USB | USB 2.0 |
Data format | XML |
Fiber optic connector | Optional SMA905D |
APPLICATION
-
High precision scientific and laboratory measurement.
FEATURE
PID controlled Peltier cooling of the sensor for stable dark current and increased dynamic range
-
USB 2.0 connection for PC connection with universal user-friendly software
-
Single instrument can be used with multiple optical accessories
- Automatic accessory detection
For more information please visit: