Single Flame Atomic Absorption Spectrophotometer
FAAS Spectrophotometer
The Single Flame Atomic Absorption Spectrophotometer (FAAS) AS2000 is a brand new product carefully crafted by Optosky. The original optical path design greatly improves the sensitivity in the ultraviolet region. The outstanding mechanical and optical system, coupled with excellent software, ensure the accuracy of measurement.
SPECIFICATION
Lo
|
Model |
AS2000 |
|
Wavelength Range |
190~900nm |
|
Grating Line Density |
1800 lines /mm |
|
Absorbance Range |
0–2.5ABS |
|
Wavelength Repeatability |
±0.1nm |
|
Wavelength Accuracy |
Full spectrum ±0.2 nm |
|
Optical System |
Integrated optical platform, fully enclosed
optical system (single beam) |
|
Detector |
Photomultiplier tube |
|
Resolution |
Able to separate manganese doublet lines
(279.5 and 279.8 nm) with a spectral bandwidth of 0.2 nm and a valley-to-peak
energy ratio of <30% |
|
Spectral Slits |
0.1nm,0.2nm,0.4nm,1nm,1.2nm.2.0nm(automatically
switchable) |
|
Background Correction Technology |
D2 background subtraction (background signal 1
ABS, background reduction capability ≥50 times) |
|
Static Baseline Drift |
≤0.004ABS/30min( Cu) |
|
Lamp Holder |
4-lamp turret |
|
Characteristic Concentration (Copper) |
≤0.025ug/ml |
|
Measurement Repeatability(Copper) |
≤0.5%(Cu,Absorbance>0.8ABS) |
|
Detection Limit |
Cd ≤0.3pg |
|
Gas Flow Control |
Needle valve control |
|
Safety Protection |
Automatic gas cut-off for low pressure, power
interruption, abnormal flameout, and burner mismatch; |
|
Background Subtraction Method |
Self-absorption and deuterium lamp background
subtraction methods,can correct 1A background. When the background signal is 1A, the
background deduction ability is ≥50 times |
|
Burner |
Air-acetylene flame burner 100mm |
|
Ignition Method |
Automatic ignition |
|
Ignition Dynamic Baseline Drift |
≤0.004ABS/30min(Cu) |
|
Dimensions |
700*500*530(mm) |
|
Weight |
80kg |
Feature
- HCL:4 hollow cathode lamps (can be installed)
- Safety control for abnormal situations, such as insufficient pressure, air leakage, flameout.
- Provides 6 levels of slit (automatic switching)
- The software adds a method storage function. Users can store the standard curve and call it up at any time, which can save analysis time.
- Good stability, wide measurement range, low detection limit
Application
- Minerals:rare earth analysis and precious metals analysis
- Environmental:Environmental Protection &Water quality testing
- Material science:alloy materials & building materials
- Scientific research: Elemental quantitative analysis in scientific research such as medical and health, and higher education institutions