Infrared Multi-Gas Analyzer GF330
Gas Analyzer
Advanced multi-gas sensing solutions that can sense a variety of gases at a time. Explosion-proof products adapt to complex working conditions.
Description
The infrared gas analyzer adopts non-dispersive infrared technology (NDIR, Non-Dispersive InfraRed). NDIR is a method based on the Lambert-Beer law gas absorption theory. After the infrared radiation emitted by the infrared light source is absorbed by a certain concentration of gas, the spectral intensity proportional to the gas concentration will change, so the concentration of the gas to be measured can be reversed by calculating the change in spectral light intensity.
Another core technology of infrared gas analyzer is based on infrared correlation filtering technology and self-designed long optical path gas absorption cell to realize quantitative analysis of gas in infrared band, which has the characteristics of high precision, good stability and fast response time.
FEATURES
- Continuous measurement of SO2, NO, CO, CO2, CH4, N2O, O2, SF6 and other gas concentrations
- Support 4-20mA analog output, RS232, RS485, network port and other data output methods
- Easy to operate, quick to set up
- Color large-screen LCD operation interface, supports switching between Chinese and English
- Directly complete parameter setting, measurement and calibration through the menu
- Measuring range can be customized
APPLICATION
- Scientific research fields
- Agricultural field
- Industrial field
- Environmental protection field
- Security field
Parameter
| Measuring principle | Infrared absorption (NDIR) |
| Measuring gas | CO, CO2, O2, etc. (expandable: SO2, NO, N2O, CH4, SF6; replace the corresponding sensor module according to customer needs) |
| Measuring range | SO2: 0-100ppm to 0-2000ppm NO: 0-1000ppm to 0-30000ppm CO: 0-100ppm to 0-100% Vol CO2: 0-100ppm to 0-100% Vol CH4: 0-50ppm to 0-5% Vol SF6: 0-50ppm to 0-1000ppm N2O: 0-50ppm to 0-500ppm O2: 0-5% Vol to 0-25% Vol |
| Preheat time | 5 minutes (depending on the sensor) |
| Response time | ≤5s |
| Stability | Zero drift: ≤1% FS/week Range drift: ≤1% FS/week |
| Output interface | Numerical output: RS232/RS485 Switch output: IN/OUT (supports 8 channels) Analog output: 4-20mA (supports 4 channels) |
| Gas inlet flow | 0.5L-1L/min |
| Linearity error | ≤1% FS |
| Repeatability | ≤1% |
| Ambient temperature effect | When the ambient temperature changes by 10 °C, zero point and span change ≤2% |
| Atmospheric pressure effect | Per change ≤1%, (allowable atmospheric pressure range) ≤2% |
| Use environment | Temperature: 0-45 °C Humidity: 0-90%RH Atmospheric pressure: 700-1200 hPa |
| Power supply | AC220V |
| Dimensions | 19 inch 4U sheet metal chassis |
| Weight | 12 kg |