CalibraSpec™ 6500A Spectroradiometer
Elevate Your Lab’s Optical Analysis Capabilities
The CalibraSpec 6500A spectroradiometer delivers unparalleled spectral accuracy and stability, making it an ideal choice for advanced laboratory work.
Key Benefits for Laboratory Researchers:
- Exceptional spectral resolution across the full UV-Vis-NIR range (350–2500 nm), enabling detailed characterization of materials and samples.
- Thermoelectrically cooled detectors ensure consistent repeatability, drift stability, and low noise for high-confidence results.
- Radiometric calibration traceable to NIST standards supports rigorous internal testing, calibration transfer, and quality control efforts.
- Integrated with DARWin™ SP software for intuitive data acquisition and real-time monitoring of detector temperatures and performance.
Whether you’re conducting material identification, calibration transfer, irradiance measurements, or rigorous spectral analysis, the CalibraSpec 6500A is engineered to elevate your lab’s capabilities and accelerate discovery.
Features
- Drift stability of 0.1% for greater accuracy of long-term stability measurements of integrating spheres and light sources.
- A temperature controller maintains the instrument housing at a stable temperature to minimize warm-up time.
- All detector temperatures are integrated into DARWin™ SP Data Acquisition software readout for monitoring.
- Automatic integration of all detectors and dark current correction for unparalleled signal-to-noise ratio.
- High-transmission fiber optic cable radiometrically calibrated to NIST standard.
- Optional radiometrically calibrated optics such as lenses and cosine receptors.
Specification
| Model | CalibraSpec 6500A |
| Spectral Range | 350-2500 nm |
| Spectral Resolution | 1.5 nm @ 700 nm |
| 3 nm @ 1500 nm | |
| 3.8 nm @ 2100 nm | |
| Sampling Bandwidth (nm) | 2151 Sampling channels |
| Data output in 1 nm increments | |
| Spectrometer Type | 3 Diffraction Gratings |
| Detector(s) | 1024-element UV-enhanced TE-cooled Si Array |
| 512-element TE-cooled InGaAs array | |
| 512-element TE-cooled extended InGaAs array | |
| Calibration | Factory calibrated for radiance and/or irradiance using NIST traceable source (depending upon optics selection) |
| Noise Equivalence Radiance W/cm2/nm/sr (1.2m fiber optic) | 0.4x10-9 @ 400 nm |
| 0.2x10-9 @ 1500 nm | |
| 2.0x10-9 @ 2100 nm | |
| Stray Light | ≤0.1%; VNIR: <0.03%; SWIR <0.02% |
| Software Included | DARWin™ Data Acquisition |
| Data output in ASCII format for easy post processing. | |
| Compatible with: All post-processing software, EZ-ID™ software for instant identification & spectral library building and Eigenvector chemometrics modeling software. | |
| Power | 12V, 33W |
| Dimensions (millimeters | inches) | 315 x 221 x 112 mm |
| 12.4 x 8.7 x 4.4 in | |
| Weight | 13.8lbs | 6.3kg |
| Interface | USB, Wireless Bluetooth® Connection |
| Integration Time | 1 - 1000 ms |
| Max Radiance | VNIR: 10 x Solar; SWIR: 2 x Solar |
| Wavelength Reproducibility (nm) | 0.1 |
| Wavelength Accuracy (nm) | 0.5 |
| Automatic Exposure | Yes |
| Shutter for Dark Scans | Yes |
| TTL & Phototriggering for pulsed measurement | No |
Applications Of CalibraSpec 6500A Spectroradiometer
- Mineral unmixing
- Soil identification
- Vegetation studies
- Materials identification
- Microbial diversity research