ORNET

CalibraSpec™ 6500A Spectroradiometer

Elevate Your Lab’s Optical Analysis Capabilities

The CalibraSpec 6500A spectroradiometer delivers unparalleled spectral accuracy and stability, making it an ideal choice for advanced laboratory work.

Key Benefits for Laboratory Researchers:

  • Exceptional spectral resolution across the full UV-Vis-NIR range (350–2500 nm), enabling detailed characterization of materials and samples.
  • Thermoelectrically cooled detectors ensure consistent repeatability, drift stability, and low noise for high-confidence results.
  • Radiometric calibration traceable to NIST standards supports rigorous internal testing, calibration transfer, and quality control efforts.
  • Integrated with DARWin™ SP software for intuitive data acquisition and real-time monitoring of detector temperatures and performance.

Whether you’re conducting material identification, calibration transfer, irradiance measurements, or rigorous spectral analysis, the CalibraSpec 6500A is engineered to elevate your lab’s capabilities and accelerate discovery.

CalibraSpec 6500A Spectroradiometer

Features

  • Drift stability of 0.1% for greater accuracy of long-term stability measurements of integrating spheres and light sources.
  • A temperature controller maintains the instrument housing at a stable temperature to minimize warm-up time.
  • All detector temperatures are integrated into DARWin™ SP Data Acquisition software readout for monitoring.
  • Automatic integration of all detectors and dark current correction for unparalleled signal-to-noise ratio.
  • High-transmission fiber optic cable radiometrically calibrated to NIST standard.
  • Optional radiometrically calibrated optics such as lenses and cosine receptors.

Specification

ModelCalibraSpec 6500A
Spectral Range350-2500 nm
Spectral Resolution1.5 nm @ 700 nm
3 nm @ 1500 nm
3.8 nm @ 2100 nm
Sampling Bandwidth (nm)2151 Sampling channels
Data output in 1 nm increments
Spectrometer Type3 Diffraction Gratings
Detector(s)1024-element UV-enhanced TE-cooled Si Array
512-element TE-cooled InGaAs array
512-element TE-cooled extended InGaAs array
CalibrationFactory calibrated for radiance and/or irradiance using NIST traceable source (depending upon optics selection)
Noise Equivalence Radiance W/cm2/nm/sr (1.2m fiber optic)0.4x10-9 @ 400 nm
0.2x10-9 @ 1500 nm
2.0x10-9 @ 2100 nm
Stray Light≤0.1%; VNIR: <0.03%; SWIR <0.02%
Software IncludedDARWin™ Data Acquisition
Data output in ASCII format for easy post processing.
Compatible with: All post-processing software, EZ-ID™ software for instant identification & spectral library building and Eigenvector chemometrics modeling software.
Power12V, 33W
Dimensions (millimeters | inches)315 x 221 x 112 mm
12.4 x 8.7 x 4.4 in
Weight13.8lbs | 6.3kg
InterfaceUSB, Wireless Bluetooth® Connection
Integration Time1 - 1000 ms
Max RadianceVNIR: 10 x Solar; SWIR: 2 x Solar
Wavelength Reproducibility (nm)0.1
Wavelength Accuracy (nm)0.5
Automatic ExposureYes
Shutter for Dark ScansYes
TTL & Phototriggering for pulsed measurementNo

Applications Of CalibraSpec 6500A Spectroradiometer

  • Mineral unmixing
  • Soil identification
  • Vegetation studies
  • Materials identification
  • Microbial diversity research